| UVC Germicidal Irradiation for Air Handling Units (Commercial). |
ALTRU-V (V-Ray™Sus) |
ULTRAVIOLET LAMP SYSTEM FAN/COIL, UNIT VENTILATOR PTAC, AND HEAT PUMPS. |
| APPLICATION |
The V-Ray 's design allows for ease of installation in almost any system size from 12” to 64” in which with power requirements from 100Vac to 277Vac. V-Ray fixtures can be mounted in any orientation to properly irradiate the target surface. The V-Ray can be installed to irradiate coils and drain pans where they degrade causing overflow of water that can cause significant damage to surrounding material (e.g., ceiling tiles, carpet, etc.). The patent pending system can be installed using a permanently fixed lamp clip or via a patent pending magnetic lamp clip design. The V-Ray components are UL listed and the system is listed with ETL. |
| 1. Mount Ballast Housing, Hard-wire 2. Drill Hole for Lamp Power Cable (32”) 3. Mount Lamp Clasps 4. Snap UV Lamp into Clasp
(Note: Ballast housing may also be installed in the air stream if desired) |
 |
|
SPECIFICATIONS |
UVC Fixturing – Fixturing consists of a lamp, lamp clasps, UVC resistant wiring harness, power supply and power supply housing.
Lamp – Each lamp contains no more than 5 milligrams of mercury. Lamp life is 9000 hours with no more than a 20% output loss at the end of the lamps life. Lamps are constructed with UVC resistant bases and do not produce ozone. When used for surface irradiation, the lamp selected will be equal to or no less than 90% of the coil width.
Irradiation – Fixture less lamps are to be installed in sufficient quantity and in such a manner as to provide an equal distribution of UVC energy. When installed, the UVC energy produced will be of the lowest possible reflected and shadowed losses. Note: the applied energy and its distribution shall be verifiable using third party algorithms. |

ALTRU-V (V-Ray™Sus). |
Intensity – The minimal UVC energy striking a surface is sufficient to continuously destroy a mono layer of mold and bacteria in less than six hours when at 55-135°F. The third party modeling shall be available to determine the destruction time for at least four of the most common fan coil surface microbes.
Lamp Wire – Is of sufficient length to facilitate lamp connection to a remotely located ballast. It includes a grommet to facilitate safe passage through sheet metal and into the ballast housing. Lamps are capable of being mounted anywhere in the system and/or as shown on the plans.
Power Supply – Power supplies are of the high efficiency electronic type, matched to the lamp and designed to optimize UVC photon production and reliability. They are UL Listed and labeled for use in air-streams of 55-135°F. They are capable of producing the specified output and organism destruction as listed under Irradiation and Intensity above at no more than 13 Watts of power consumption for each square foot of treated, cross sectional area.
Installation – Fixturing are electrically terminated to within factory supplied ballast housings to meet NEC and local codes. Lamps should be mounted to irradiate the intended surface(s) as well as all of the available line of sight air stream by proper placement and incident angle reflection.
Safety – To protect maintenance personnel, all access panels and doors to the UVC assembly and/or within view of the UVC assembly must include mechanical interlock switche(s) to insure that the UVC assembly will be de-energized when any of these accesses are opened.
|
 |